ICT MEDICAL
Professional product collection

Molding cog and specialty threads

FIGO Thread Systems

The portfolio covers FIGO C, Double X, M, XZ, X and BOMB, plus YOUTH40 and YOUTH20 molding profiles. Supplier category names are technical selection references, not individual treatment guidance.

FIGO Thread Systems — Molding cog and specialty threads

Specifications

ParameterProduct information
ModelFIGO C / Double X / M / XZ / X / BOMB
Molding profilesYOUTH40 / YOUTH20
Illustrated polymer familiesPDO / PCL

Models and configurations

Supplier categoryModelNeedleThread lengthUSP
NoseFIGO C19G × 38 mm40 mm2
NoseFIGO C19G × 60 mm80 mm2
NoseFIGO Double X19G × 38 mm40 mm2
NoseFIGO Double X19G × 60 mm80 mm2
InfraorbitalFIGO M30G × 38 mm50 mm7-0
InfraorbitalFIGO Double X19G × 60 mm210 mm2
Brow / foreheadFIGO XZ21G × 80 mm290 mm2-0
Brow / foreheadFIGO XZ23G × 60 mm190 mm3-0
Brow / foreheadFIGO X21G × 80 mm150 mm2-0
Double chinFIGO X double-needle19G × 110 mm420 mm2
Double chinFIGO X single18G × 100 mm170 mm3
ScalpFIGO M30G × 25 mm30 mm7-0
NasolabialFIGO BOMB21G × 38 mm50 mm5-0 × 9
NasolabialFIGO BOMB21G × 60 mm70 mm5-0 × 9

YOUTH molding profiles

The catalogue illustrates PDO/PCL families and lists a 420 mm thread for YOUTH40. It does not state the thread length for YOUTH20. Select polymer and exact model together; follow the manufacturer’s IFU for indications and compatibility.

ODM and documentation

The supplied portfolio offers an ODM process: select reference models; customize configurations, labels and packaging; prepare technical documentation; then review samples, approvals and order conditions.

The 2024 MYTHCO source portfolio displays CE, ISO 13485 and GMP marks. CE applicability is device/model-specific; ISO 13485 refers to the manufacturer’s quality-management system, and GMP to manufacturing quality controls.

Complete English source detail

The complete English product-guide text is retained below. The localized overview and specification tables above are a structured adaptation; the PDF remains the original manufacturer/source document.

The FIGO thread-system collection brings together FIGO C, Double X, M, XZ, X and BOMB models, alongside YOUTH 40 and YOUTH 20 molding profiles. The catalogue organizes reference configurations by nose, infraorbital, brow and forehead, double-chin, scalp and nasolabial categories.

Thread portfolio overview

The tables reproduce the supplier catalogue categories and reference configurations for technical selection. Each configuration retains its listed gauge, needle reference, thread length and USP designation.

The molding-profile page illustrates PDO / PCL families. The brochure specifies that the polymer and exact model are to be confirmed together when selecting the product.

Nose references: FIGO C and FIGO Double X

FIGO C is listed in two configurations. The catalogue states that FIGO Double X has the same two source-listed configurations for this category.

ModelNeedle referenceThread lengthUSP
FIGO C19G × 38 mm40 mm2
FIGO C19G × 60 mm80 mm2
FIGO Double X19G × 38 mm40 mm2
FIGO Double X19G × 60 mm80 mm2

Infraorbital references: FIGO M and FIGO Double X

ModelNeedle referenceThread lengthUSP
FIGO M30G × 38 mm50 mm7-0
FIGO Double X19G × 60 mm210 mm2

YOUTH series: molding profiles

YOUTH 40 and YOUTH 20 are presented as molding reference platforms in PDO / PCL families. The source specifies a 420 mm thread length for YOUTH 40.

The original YOUTH illustration states that YOUTHread is supplied to participants who have attended the manufacturer’s training course or to licensed medical practitioners.

ModelProfileThread length stated in the source
YOUTH 40Molding profile; PDO / PCL family illustration420 mm
YOUTH 20Molding reference platform; PDO / PCL family illustrationNot stated in the supplied catalogue

Brow and forehead references: FIGO XZ and FIGO X

ModelNeedle referenceThread lengthUSP
FIGO XZ21G × 80 mm290 mm2-0
FIGO XZ23G × 60 mm190 mm3-0
FIGO X21G × 80 mm150 mm2-0

Double-chin references: FIGO X

Model / formatNeedle referenceThread lengthUSP
FIGO X / Double-needle19G × 110 mm420 mm2
FIGO X / Single18G × 100 mm170 mm3

Scalp reference: FIGO M

ModelNeedle referenceThread lengthUSP
FIGO M30G × 25 mm30 mm7-0

Nasolabial references: FIGO BOMB

The source lists two FIGO BOMB configurations and prints the USP notation as 5-0 × 9.

ModelNeedle referenceThread lengthUSP source notation
FIGO BOMB21G × 38 mm50 mm5-0 × 9
FIGO BOMB21G × 60 mm70 mm5-0 × 9

Professional documentation

The area names are the supplier’s technical reference categories. Exact indications, needle compatibility and clinical instructions follow the approved manufacturer IFU.

ODM configuration and branding

ODM support is available for product configuration, branding and packaging. AB LIFE GLOBAL presents a four-step process, from selecting reference models to reviewing samples and order conditions.

StepFocusDetails
01 / SelectReference models and desired specificationsChoose the product family and reference configurations for the intended portfolio.
02 / CustomizeConfigurations, labels and packagingDefine the configuration, label and packaging requirements.
03 / DocumentTechnical files and applicable credentialsPrepare the technical documentation and applicable credential information.
04 / ReviewSampling, approval and order conditionsReview samples, approvals and order conditions.

Manufacturer-source portfolio credentials

The 2024 MYTHCO source portfolio displays CE, ISO 13485 and GMP marks. The brochure presents these as manufacturer-supplied portfolio credentials, with CE applicability determined by the particular device and model.

Mark displayed in the source portfolioScope described in the brochure
CEDevice- and model-specific applicability.
ISO 13485Manufacturer quality management system.
GMPManufacturing quality controls.

Professional enquiry

Include your company, destination country, selected model and required quantity. This opens your email application; it does not send or store an enquiry automatically.

alexmoon@ictmedicalco.com ↗
WhatsApp+971 50 571 7673